Settings
Under Advanced options:
Scroll the page, JavaScript instructions, Wait after page load and Proxy country need the proxy, so the editor hides them while Disable proxy is on. Whitelisted private domains is for a direct read, so it shows only while Disable proxy is on. With Disable proxy on, the node refuses a page whose address is private unless its domain is whitelisted, reads at most 20 MB of a page and gives up on a page after 15 seconds.
Outputs
At Depth 0, Pages and Page URLs hold one value each. At Depth 1 or 2 they are lists with one item per page, so a step bound to them runs once per page. Links Found is always a list.
When a linked page cannot be read, the node leaves it out of Pages and Page URLs and names it in a warning. The other pages still come through.
When a read fails
The node checks its settings before it reads anything:- A Depth outside 0 to 2, a Wait outside 0 to 15, JavaScript instructions that are not a JSON list, or a Proxy country that is not in the list shows an error on the field. Over the API or MCP, validation reports it.
- When a setting is bound to a variable, the same check runs when the step starts, before any request.
- An empty URL, or text that is not a web address, fails the step with a message that says so.
Set the step’s On failure option to continue the flow when a page cannot be read.